Document Type

Article

Publication Date

8-24-2026

Department

Department of Chemical Engineering

Abstract

Carbon microelectrodes are attractive for microfluidic biosensing due to their wide potential window, low overpotentials, chemical stability, and compatibility with low-cost microfabrication. Pyrolysis of photopatterned SU-8 offers a scalable route to carbon electrode fabrication; however, conventional two-step pyrolysis often leads to adhesion issues, geometric distortion, and limited surface area in low-aspect-ratio planar designs. These constraints restrict performance and broader adoption in analytical microdevices. Hematocrit determination, a clinically essential diagnostic measurement, requires electrodes with high reproducibility and robust electrochemical response. A simplified fabrication strategy that improves electrode surface area and performance while maintaining low-aspect-ratio planar geometries remains unresolved. We developed a three-step pyrolysis protocol that enables fabrication of low-aspect-ratio planar SU-8–derived carbon electrodes with both micro- and millimeter-scale features while improving structural integrity and surface morphology. The electrodes were integrated into a PDMS-based microfluidic device for hematocrit detection by measuring current responses of red blood cells suspended in phosphate-buffered saline at 100 V for 30 s. A linear correlation was observed between current and red blood cell concentration. The device achieved 3.6% precision and 3.8% accuracy for hematocrit determination, comparable to previously reported platinum-based systems (2.8% precision, 2.6% accuracy). Surface characterization via field-emission scanning electron microscopy and atomic force microscopy revealed a 25% increase in surface area relative to platinum electrodes, resulting from 2.7 times greater roughness and 58 times greater thickness. These structural enhancements reduced charge-transfer and concentration overpotentials, improving electrochemical performance. This work introduces a reproducible three-step pyrolysis method that overcomes long-standing limitations in the fabrication of low-aspect-ratio pyrolytic carbon electrodes. By increasing electroactive surface area without complex coatings or noble metals, the approach enables high-performance, low-cost microelectrodes suitable for integrated biosensing. The demonstrated equivalence to platinum electrodes in hematocrit detection highlights its translational potential for scalable diagnostic microdevices.

Publisher's Statement

© The Author(s) 2026. Publisher’s version of record: https://doi.org/10.1007/s10544-026-00838-6

Publication Title

Biomedical Microdevices

Version

Publisher's PDF

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.