Automatic reorientation by deep learning to generate short-axis SPECT myocardial perfusion images

Document Type

Article

Publication Date

3-1-2023

Department

Department of Applied Computing

Abstract

Background: Single photon emission computed tomography (SPECT) myocardial perfusion images (MPI) can be displayed both in traditional short-axis (SA) cardiac planes and polar maps for interpretation and quantification. It is essential to reorient the reconstructed transaxial SPECT MPI into standard SA slices. This study is aimed to develop a deep-learning-based approach for automatic reorientation of MPI. Methods: A total of 254 patients were enrolled, including 226 stress SPECT MPIs and 247 rest SPECT MPIs. Fivefold cross-validation with 180 stress and 201 rest MPIs was used for training and internal validation; the remaining images were used for testing. The rigid transformation parameters (translation and rotation) from manual reorientation were annotated by an experienced nuclear cardiologist and used as the reference standard. A convolutional neural network (CNN) was designed to predict the transformation parameters. Then, the derived transform was applied to the grid generator and sampler in spatial transformer network (STN) to generate the reoriented image. A loss function containing mean absolute errors for translation and mean square errors for rotation was employed. A three-stage optimization strategy was adopted for model optimization: (1) optimize the translation parameters while fixing the rotation parameters; (2) optimize rotation parameters while fixing the translation parameters; (3) optimize both translation and rotation parameters together. Results: In the test set, the Spearman determination coefficients of the translation distances and rotation angles between the model prediction and the reference standard were 0.993 in X axis, 0.992 in Y axis, 0.994 in Z axis, 0.987 along X axis, 0.990 along Y axis and 0.996 along Z axis, respectively. For the 46 stress MPIs in the test set, the Spearman determination coefficients were 0.858 in percentage of profusion defect (PPD) and 0.858 in summed stress score (SSS); for the 46 rest MPIs in the test set, the Spearman determination coefficients were 0.9 in PPD and 0.9 in summed rest score (SRS). Conclusions: Our deep learning-based LV reorientation method is able to accurately generate the SA images. Technical validations and subsequent evaluations of measured clinical parameters show that it has great promise for clinical use.

Publication Title

Journal of Nuclear Cardiology

Share

COinS