Temperature variation in the absorber plate of an air heating flat plate solar collector

Document Type

Article

Publication Date

1-1-1981

Abstract

A flat plate solar collector is modelled as a rectangular channel of highwidth to gap ratio with air entering the collector with a fully developed turbulent velocity prof He. One plate of the collector is subjected to a uniform heat fluxwith the other plate heavily insulated. Experimental values of friction factor andheated plate temperature in the thermal entrance region are presented and comparedwith analytical predictions. It is shown that there will be significant plate temperature variation in the thermal entrance region particularly at low flow rates. It is also shown that neglecting conduction effects in the absorber plate will not lead to any significant errors in estimating absorber plate temperature variation.Tabulated values of dimensionless plate temperature for different values of the dimensionless distance from the leading edge for several Reynolds number are presented. © 1981 by ASME.

Publication Title

Journal of Solar Energy Engineering, Transactions of the ASME

Share

COinS